The survey report must communicate findings clearly to:

  • A. Building owners, occupants, and professionals who may not be surveyors
  • B. No one; findings are confidential
  • C. Only moisture specialists
  • D. Only building professionals

正解:A


質問 # 28
To confirm the presence of a DPC and assess its integrity, the surveyor should:

  • A. Only use visual methods
  • B. Physically locate it through inspection, breaching if necessary with permission, and test its continuity
  • C. Never investigate the DPC
  • D. Assume it exists without checking

正解:B


質問 # 29
The main objective of rising damp control is to:

  • A. Ignore the issue
  • B. Mask the problem
  • C. Prevent moisture rising by introducing a DPC barrier and managing any existing moisture/salts
  • D. Remove all masonry

正解:C


質問 # 30
When a surveyor identifies that previous damp treatments have been unsuccessful, investigation should focus on:

  • A. Only repeating the same treatment
  • B. Abandoning investigation
  • C. Understanding why treatment failed (inadequate diagnosis, incomplete treatment, new moisture sources), before recommending revised approach
  • D. Assuming property is untreatable

正解:C


質問 # 31
A surveyor reports on penetrating damp in a cavity wall property. The report should include:

  • A. Only moisture meter readings
  • B. Only recommendations without investigation details
  • C. Location of damp internally, corresponding external defects photographed, assessment of cavity integrity, insulation condition, and recommended repair prioritization
  • D. Only aesthetic observations

正解:C


質問 # 32
When reporting on timber decay potentially related to dampness, the surveyor should:

  • A. Only recommend timber replacement
  • B. Ignore moisture in timber assessment
  • C. Only diagnose damp
  • D. Assess both moisture condition and timber decay severity; note if moisture exceeds 18-20% (fungal risk)

正解:D


質問 # 33
According to BS 5250:2021, moisture management in buildings requires consideration of:

  • A. Thermal performance only
  • B. Aesthetic performance only
  • C. Structural design only
  • D. Thermal performance and moisture performance

正解:D


質問 # 34
BS 6576:2005 requires chemical DPC injection to penetrate to approximately:

  • A. 80-90% of wall thickness
  • B. 50-75% of wall thickness
  • C. Full thickness with breakthrough
  • D. 25% of wall thickness

正解:A


質問 # 35
BS 5250:2021 states that relative humidity should ideally be maintained below:

  • A. 85-90%
  • B. 50%
  • C. 65-70%
  • D. 30%

正解:C


質問 # 36
Spot ventilation (such as kitchen/bathroom extraction) should operate:

  • A. During and for a period after moisture-generating activities (cooking, bathing) with exhaust to the outside
  • B. Always, even when not needed
  • C. Never
  • D. Only in winter

正解:A


質問 # 37
To diagnose condensation as opposed to rising or penetrating damp, the surveyor should observe:

  • A. Surface condensation without salt deposits, appearing in cold corners and on windows
  • B. Tide marks at ground level
  • C. Damp only after rainfall
  • D. Moisture at all heights

正解:A


質問 # 38
Asbestos awareness is important for surveyors because:

  • A. It is not relevant to damp surveying
  • B. Asbestos poses no health risk
  • C. Asbestos may be present in older buildings and requires specialist handling if disturbed
  • D. Only electricians need to know about asbestos

正解:C


質問 # 39
The surveyor should investigate the external envelope when diagnosing penetrating damp to:

  • A. Identify and record defects causing the damp ingress
  • B. Record aesthetic features only
  • C. Always recommend cavity wall insulation
  • D. Ignore it

正解:A


質問 # 40
Under Building Regulations, which Approved Document specifically addresses basement waterproofing requirements?

  • A. Approved Document F
  • B. Approved Document B
  • C. Approved Document L
  • D. Approved Document C

正解:D


質問 # 41
Condensation typically appears as:

  • A. Brown staining on brickwork
  • B. Damp patches linked to external defects
  • C. Black mould on walls, ceilings, windows, and cold surfaces
  • D. Tide marks with salt deposits