お手軽に合格させる 最新BICSI INST1-V8問題集には119問があります [Q55-Q70]

Share

お手軽に合格させる 最新BICSI INST1-V8問題集には119問があります

最新のINST1-V8学習ガイド2025年最新の- 提供するのはテストエンジンとPDF

質問 # 55
Which of the following is used to perform continuity and length tests for coaxial cable?

  • A. VFL (visual fault locator)
  • B. OTDR (optical time domain reflectometer
  • C. OLTS (optical loss test set)
  • D. TDR (Time domain reflectometer) with an adapter

正解:D


質問 # 56
You are terminating a category 3 cable. What is the maximum permissible amount of untwisting?

  • A. 75 mm (3")
  • B. 25 mm (1")
  • C. 100 mm (4")
  • D. 38 mm (1.5")

正解:A


質問 # 57
Which of the following must be measured before the length of a coaxial cable can be calculated?

  • A. Insertion loss
  • B. Propagation delay
  • C. DC loop resistance
  • D. Delay skew

正解:C


質問 # 58
Which of the following topologies is the recommended topology for distribution systems in campus environments?

  • A. Tree
  • B. Star
  • C. Hierarchical Star
  • D. Ring

正解:C


質問 # 59
Which of the following tools is a low-cost cable verifier that can be used to test for opens, shorts, crossed pairs, and miswires in 4- pair cables?

  • A. Qualification tester
  • B. Wire map tester
  • C. Telephone test set
  • D. TDR

正解:B


質問 # 60
Which type of optical fiber cable should be color coded with an Orange outer cable sheath?

  • A. MM with a 100 um core diameter
  • B. Polarization maintain SM optical fiber
  • C. Dispersion-shifted SM optical fiber
  • D. SM optical fiber

正解:A


質問 # 61
Which of the following results from the different optical path lengths in a multimode fiber?

  • A. Attenuation
  • B. Modal dispersion
  • C. Chromatic dispersion

正解:B


質問 # 62
What is the specified performance level for Category 6 cable?

  • A. 100 MHz
  • B. 500 MHz
  • C. 250 MHz
  • D. 600 MHz

正解:C


質問 # 63
Which of the following is a building-serving space that houses large pieces of common active equipment?

  • A. Battery room
  • B. Mechanical Room
  • C. TE
  • D. ER
  • E. TR

正解:D


質問 # 64
Which of the following tend to cause sheath damage during cable pulling?

  • A. EMT/ENT
  • B. FMC/FMT
  • C. RMC/IMC

正解:B


質問 # 65
Which is a keyed, contact, moderate loss connector in present use today that is pull & wiggle-proof?

  • A. SMA 906
  • B. Straight Tip (ST)
  • C. Subscriber Connector (SC)
  • D. Opti-Jack

正解:B


質問 # 66
How long does it take someone to form a first impression?

  • A. 1 to 2 minutes
  • B. 30 minutes to 1 hour
  • C. 5 to 10 minutes
  • D. 10 to 15 seconds

正解:D


質問 # 67
A grey backboard should be used to identify _____ backbone cable?

  • A. First-level
  • B. Second-level
  • C. Intrabuilding

正解:B


質問 # 68
What is the recommended minimum amount of aisle space between and around equipment?

  • A. 1 m (3.3')
  • B. 1.2 m (4')
  • C. 1.52 m (5')
  • D. 0.6 m (2')

正解:A


質問 # 69
Which of the following is the bonding connection point for telecommunications systems and equipment in the area by a telecommunication space?

  • A. BBC
  • B. TEBC
  • C. RBB
  • D. SBB

正解:D


質問 # 70
......

INST1-V8問題集と試験テストエンジン:https://www.passtest.jp/BICSI/INST1-V8-shiken.html

最新版を今すぐ試そうINST1-V8練習テスト問題解答:https://drive.google.com/open?id=1MDfvCRp4Vu4S1CfZ5Byh9ASaw-vzm21S