質問 # 19
What is the difference between a raised floor and a solid floor?

  • A. Solid floor is more flexible and adaptable to changing needs
  • B. Solid floor allows for better cooling efficiency and higher load capacity
  • C. Raised floor allows for better airflow and cable management
  • D. Raised floor is cheaper and easier to install

正解:C


質問 # 20
What is the minimum distance from the bottom of the access floor to the top of the cable tray?

  • A. 5 inches
  • B. 4 inches
  • C. 2 inches
  • D. 3 inches
  • E. 1 inch

正解:C


質問 # 21
What is the function of an emergency generator?

  • A. provide backup power to IT equipment only
  • B. supply power to the restrooms during a utility outage
  • C. all of the above
  • D. back up office lighting

正解:C


質問 # 22
What three things limit the amount of IT equipment per rack?

  • A. staffing availability, security measures, and access points
  • B. sustainability goals, partitioning requirements, and compliance mandates
  • C. power constraints, cooling constraints and lastly, rack space
  • D. fire suppression system technology, humidity levels, and network speed

正解:C


質問 # 23
What is the Fourth Preference Regarding Utility Service?

  • A. At least four circuits each from different distribution stations but fed via common feeders
  • B. One circuit from one substation, separate paths
  • C. At least two circuits from one substation fed via alternative power grid
  • D. Two balanced feeds with different voltages derived from a single distribution station

正解:B


質問 # 24
What is the recommended range for the high temperature in a data center according to ASHRAE?

  • A. 85 degrees
  • B. 75 degrees
  • C. 70 degrees
  • D. 90 degrees
  • E. 80.6 degrees

正解:E


質問 # 25
What types of electrical equipment is typically located inside the computer room

  • A. Circuit Breakers only
  • B. power distribution units, not power distribution equipment, remote power panels, and power strips
  • C. transformers only
  • D. Uninterrupted Power Supply (UPS) only

正解:B

解説:
Explanation


質問 # 26
What is the ASHRAE TC 9.9 recommended range for humidity levels in a data center?

  • A. 60-80%
  • B. 20-50%
  • C. 80-100%
  • D. 40-60%

正解:D


質問 # 27
Which areas should generate a history of all access attempts and monitored by CCTV Security System?

  • A. Loading Docks
  • B. Storage Areas
  • C. Any concealed places
  • D. Only computer rooms
  • E. Computer rooms, Loading docks, storage areas, Staging areas and Vendor Storage

正解:E


質問 # 28
What is the ASHRAE TC 9.9 recommended range for static pressure in a data center?

  • A. 0.01-0.05 inches water gauge
  • B. 0.1-0.15 inches water gauge
  • C. 0.05-0.1 inches water gauge
  • D. 0.15-0.2 inches water gauge

正解:A


質問 # 29
What is the recommended placement of electrical distribution sub systems

  • A. install within server racks
  • B. install in dedicated electrical rooms, or, locate outside the computer room with fire rated wall
  • C. install within the computer room space on raised floor
  • D. none of the above

正解:B

解説:
Explanation


質問 # 30
where should engineering offices be located?

  • A. far away from the data center
  • B. adjacent to equipment rooms they support
  • C. inside computer room
  • D. in a separate building

正解:B


質問 # 31
What is the flame index spread rating required for all materials hosted in a containment system?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:D


質問 # 32
Where should all Storage and Unpacking activities occur?

  • A. Outside Computer room, either in Storage Rooms or Staging Areas located adjacent to Computer Room with Dedicated air Handling
  • B. Inside Computer Room
  • C. None of these
  • D. Outside the Building, at a secure location.
  • E. Near the Main Entrance of Data Center

正解:A


質問 # 33
What is the difference between N+1 and 2N redundancy?

  • A. N+1 redundancy is more flexible and adaptable to changing needs than 2N redundancy
  • B. N+1 redundancy is more reliable than 2N redundancy
  • C. 2N redundancy is more cost-effective than N+1 redundancy
  • D. N+1 redundancy means that there is one additional backup component while 2N redundancy means that there are two identical backup components

正解:D


質問 # 34
What is the recommendation regarding row length?

  • A. All
  • B. None
  • C. Do not exceed 20 racks in length and dead-end rows not to exceed ten racks long
  • D. Ten Racks in Length
  • E. Maximum twenty-five racks in each row only

正解:C


質問 # 35
What is the recommended amount of fuel supply needing to be available to a class F2 data center?

  • A. 24 hours
  • B. 18 hours
  • C. 30 hours
  • D. 12 hours
  • E. 36 hours

正解:A


質問 # 36
According to NEB, what is the recommended rate of temperature change per hour in a data center?

  • A. 72 degrees
  • B. 63 degrees
  • C. 54 degrees
  • D. 36 degrees
  • E. 45 degrees

正解:C


質問 # 37
What are the minimum separation distances for electrical and telecom services pathways to maintain from their primary and redundant feeds?

  • A. 10 meters (33 feet)
  • B. 20 meters (66 feet)
  • C. 5 meters (16 feet)
  • D. 15 meters (49 feet)

正解:B


質問 # 38
when is a battery room required to have electrolyte spill containment and exhaust systems?

  • A. when using Lithium batteries
  • B. when using Sealed lead-acid-batteries
  • C. when using Nickel Cadmium batteries
  • D. when the batteries contain liquid, free-flowing electrolyte
  • E. All of Above

正解:D

解説:
Explanation


質問 # 39
What is the clearance required for the hot aisle width?

  • A. 6 ft
  • B. 8 ft
  • C. 4 ft
  • D. 2 ft

正解:C


質問 # 40
How many air changes an hour inside an equipment room?

  • A. 0.50
  • B. 2.00
  • C. 1.50
  • D. 1.00
  • E. 0.25

正解:E


質問 # 41
what is the hydrogen maximum for a data center?

  • A. None Of These answers
  • B. 1 % of total room volume
  • C. 15%of total room volume
  • D. 20%of total room volume

正解:B


質問 # 42
What Enhanced Fujita Scale level is commonly used in wind loading calculations?

  • A. EF2,113-157mph
  • B. EF3,158-206mph
  • C. EF4,207-260 mph
  • D. EF1,73-112 mph

正解:C


質問 # 43
......