220-1101日本語練習試験テスト最新問題2026年02月
220-1101日本語試験を一発合格保証問題集!
質問 # 318
顧客はゲーム用のコンピューターを構築し、個々のコンポーネントを調達してシステムを組み立てました。OS は起動しますが、数分以内にマシンがロックアップします。お客様は問題を診断するためにコンピューターを技術者に持ち込みました。
正解:
解説:
Explanation:
correct answer is "Overclocking" and "Reduce CPU Clock speed" CPU is at 4.5 Ghz when normal is 3.2 Ghz.
Overclocking too much can cause freezes, and this is a gaming computer so the user probably took it too far.
http://blog.logicalincrements.com/2018/12/4-troubleshooting-tips-overclocking-pc/
質問 # 319
グラフィック デザイナーは、できるだけ多くの異なる角度から見たときに最も正確なカラー スペクトルを提供するラップトップを購入したいと考えています。グラフィック デザイナーの要件に最も適したディスプレイ タイプは次のどれですか。
- A. プラズマ
- B. VGA
- C. 有機EL
- D. 液晶
正解:C
解説:
Explore
The correct answer is C. OLED.
OLED stands for Organic Light-Emitting Diode, and it is a type of display technology that uses organic compounds to create light and color. Unlike LCD (Liquid Crystal Display) or Plasma displays, OLED does not require a backlight or a filter to produce images. This means that OLED can offer higher contrast, wider color gamut, and better viewing angles than other display types.
LCD displays use liquid crystals that are sandwiched between two polarizing filters and illuminated by a backlight. The liquid crystals can change their orientation and block or allow light to pass through the filters.
LCD displays can have different panel types, such as IPS (In-Plane Switching), VA (Vertical Alignment), or TN (Twisted Nematic), which affect the color accuracy, response time, and viewing angles of the display.
Plasma displays use gas-filled cells that are electrically charged to create plasma, which emits ultraviolet light. The ultraviolet light then excites phosphors that emit visible light and color. Plasma displays can produce deep blacks and high contrast, but they are also prone to image retention, screen burn-in, and high power consumption.
VGA stands for Video Graphics Array, and it is not a display type but a video interface standard that was introduced in 1987. VGA can transmit analog signals from a computer to a monitor, but it has low resolution and limited color depth compared to modern digital standards such as HDMI or DisplayPort.
Therefore, OLED is the best display type for graphic designers who want the most accurate color spectrum and the widest viewing angles. OLED displays can also be thinner and lighter than LCD or Plasma displays, which makes them ideal for laptops. However, OLED displays are also more expensive and less durable than other display types, and they may suffer from image retention or burn-in over time.
質問 # 320
ユーザーから、アプリケーション サーバーのパフォーマンスが低いという報告がありました。
説明書
サーバー 1 とサーバー 2 をクリックし、各グラフに表示される情報を確認して、交換する必要があるドライブを特定します。
サーバーのパフォーマンス低下を最小限に抑えるために、使用すべき適切な交換ドライブを選択します。
いつでもシミュレーションの初期状態に戻したい場合は、「すべてリセット」ボタンをクリックしてください。
正解:
解説:
See the detailed solution in explanation below.
Explanation:
The degraded status on Server 2 indicates a RAID-5 issue, typically due to a failed or failing drive. In RAID-5 configurations, when one drive fails, the system can still operate but with reduced performance as parity data is used to rebuild missing data on-the-fly.
Recommended Replacement Drive:
To minimize performance degradation, the replacement drive should be:
SAS HDD with the same specifications (64KB stripe size, no read-ahead, and write-back policy).
Matching the configuration exactly ensures seamless integration and optimizes recovery speed in the RAID-5 array.
In RAID-5, degraded performance is expected when one drive fails, as parity data needs to rebuild missing information during each read/write process. Replacing the failed drive restores the RAID array to optimal status, reducing the load on existing drives and returning the system to normal read/write performance. The write-back policy and disabled disk cache settings are designed to reduce latency and increase efficiency, essential for handling real-time applications.
A user reports poor performance on the
application server.
INSTRUCTIONS
Click on Server 1 and Server 2 and review
the information presented in each chart to
determine which drives need to be replaced.
Select the appropriate replacement drive
that should be used, for the least
performance degradation to the server.
A computer server with many black boxes Description automatically generated with medium confidence
A screen shot of a computer Description automatically generated
A computer screen shot of a computer Description automatically generated
A computer screen shot of a computer Description automatically generated
A computer screen shot of a computer Description automatically generated
A screenshot of a computer Description automatically generated
A screenshot of a computer Description automatically generated
質問 # 321
次のワイヤレス テクノロジーのうち、最も通信範囲とワイヤレス スループットが高いのはどれですか?
- A. 802.11ac
- B. 802.11b/ジン
- C. 802.11g
- D. 802.11ax
正解:D
解説:
802.11ax is the wireless technology that has the most range and wireless throughput among the options provided.
質問 # 322
ヘルプ デスクの技術者は、デスクトップ PC が電源の欠陥により故障したと考えています。技術者が次に実行すべき手順は次のうちどれですか?
- A. 調査結果、アクション、結果を文書化します。
- B. 問題を解決するための行動計画を策定し、解決策を実行します。
- C. 症状に基づいて外部または内部の調査を実施します。
- D. 環境またはインフラストラクチャの変化について問い合わせます。
正解:C
解説:
According to the CompTIA troubleshooting methodology, the next step after establishing a theory of probable cause is to test the theory to determine the cause. However, before testing the theory, the technician may need to conduct some research based on the symptoms and the possible cause. This may involve consulting online resources, manuals, documentation, or colleagues to find out more information about the power supply and how to test it. Research can help the technician confirm or eliminate the theory and avoid unnecessary actions or damage.
Answer A is incorrect because inquiring about environmental or infrastructure changes is part of identifying the problem, which is the first step of the troubleshooting methodology. The technician should have already done this before establishing a theory of probable cause.
Answer C is incorrect because establishing a plan of action to resolve the problem and implement the solution is the fourth step of the troubleshooting methodology. The technician should not jump to this step without testing the theory and verifying the cause.
Answer D is incorrect because documenting the findings, actions, and outcomes is the last step of the troubleshooting methodology. The technician should not do this until the problem is resolved and verified.
Reference: Troubleshooting Methodology | IT Support and Help Desk | CompTIA The technician thinks the power supply is defective, indicating an initial hypothesis but not a confirmed diagnosis. According to the CompTIA A+ Core 1 Study Guide, troubleshooting follows a structured methodology (Objective 5.5: "Given a scenario, troubleshoot problems related to motherboards, RAM, CPU, and power"). At this stage, the technician has likely identified the problem (PC failure) and gathered basic information (suspected power supply issue). The next step is to refine the theory by conducting research based on symptoms-such as checking for common power supply failure signs (e.g., no power, burning smell, or intermittent shutdowns)-before proceeding to action or documentation.
B: Conduct external or internal research based on symptoms: This involves verifying the hypothesis by reviewing symptoms against known power supply failure patterns, possibly consulting manuals, online resources, or past experiences. It ensures the technician's suspicion is grounded in evidence before proceeding.
A: Inquire about environmental or infrastructure changes: This is part of initial information gathering, typically done before forming a hypothesis, not after suspecting a specific component.
C: Establish a plan of action and implement the solution: Premature without confirming the power supply is the issue; action comes after testing the theory.
D: Document findings, actions, and outcomes: Documentation occurs after resolving the issue, not at this intermediate stage.
The study guide's troubleshooting steps prioritize research and theory validation after identifying a potential cause, making B the next logical step.
From The Official CompTIA A+ Core 1 Study Guide (220-1101):
Section 5.5, Troubleshooting Methodology:
"1. Identify the problem... Gather information from the user, identify user changes, and perform backups if applicable."
"2. Establish a theory of probable cause (question the obvious)... Conduct external or internal research based on symptoms to refine your theory."
"3. Test the theory to determine cause... Once confirmed, move to planning and action."
"4. Establish a plan of action to resolve the problem and implement the solution."
"5. Verify full system functionality..."
"6. Document findings, actions, and outcomes."
Implication: After suspecting a power supply failure (step 1), the technician moves to step 2-researching symptoms-before testing or acting.
Section 5.5, Power Supply Issues:
"Power supply failure symptoms-No power, system won't boot, intermittent shutdowns, or a burning smell... Research common indicators online or in documentation to confirm the issue before replacing components." These excerpts show that researching symptoms follows the initial hypothesis and precedes actionable steps, aligning with option B.
Additional Reasoning:
Current Stage: The technician has a theory ("defective power supply") but hasn't confirmed it. Research bridges the gap between suspicion and certainty.
Power Supply Symptoms: Symptoms like no power or random reboots need validation-e.g., checking if fans spin or if there's a capacitor failure-which research can guide.
CompTIA Methodology: The six-step process is sequential. Step 1 (identify problem) is done; step 2 (establish and research theory) is next, not jumping to action (step 4) or documentation (step 6).
Other Options:
A: Asking about changes (e.g., power surges) is part of step 1, likely already done to suspect the power supply.
C: Planning and implementing (e.g., replacing the PSU) requires a tested theory, not just a suspicion.
D: Documentation is the final step, not the next one after forming a hypothesis.
References:
The Official CompTIA A+ Core 1 Study Guide (220-1101):
Section 5.5: "Given a scenario, troubleshoot problems related to motherboards, RAM, CPU, and power" (troubleshooting methodology and power supply issues).
CompTIA A+ Core 1 (220-1101) Exam Objectives:
Objective 5.5: Apply the troubleshooting process, including researching symptoms to confirm theories.
質問 # 323
技術者は、Windows BSOD がランダムに表示されたり、予期せず電源がオフになったりする古いデスクトップ システムのトラブルシューティングを行っています。すべてのシステム温度は正常範囲内です。技術者が次に行うべきことは次のうちどれですか?
- A. マザーボードのコンデンサを目視検査します。
- B. すべてのケースファンが動作していることを確認します。
- C. ソフトウェア要件と搭載されている RAM を比較します。
- D. BIOS のバージョンが搭載されている CPU をサポートしていることを確認します。
正解:A
解説:
BSoDs can be caused by poorly written device drivers or malfunctioning hardware, such as faulty memory, power supply issues, overheating of components, or hardware running beyond its specification limits. In the Windows 9x era, incompatible DLLs or bugs in the operating system kernel could also cause BSoDs.
質問 # 324
ユーザーが 3D プリンターで熱可塑性ポリウレタン (TPU) フィラメントを使用して部品を印刷しています。すべての印刷ジョブの最初のレイヤーが適切に接着されていません。
最初の層の密着性を向上させるためにユーザーが行うべきことは次のうちどれですか?
- A. 印刷速度を上げます。
- B. フィラメント流量を上げます。
- C. 冷却ファンの回転数を調整します。
- D. プリントベッド温度を下げます。
正解:B
解説:
Explanation
The correct answer is D. Raise the filament flow amount.
Filament flow amount, also known as extrusion multiplier or flow rate, is the setting that controls how much filament is extruded by the nozzle during 3D printing. It is usually expressed as a percentage of the default value, which is 100%. Increasing the filament flow amount means extruding more filament than usual, while decreasing it means extruding less1.
The filament flow amount can affect the quality and adhesion of the first layer, which is crucial for a successful 3D print. If the filament flow amount is too low, the nozzle may not extrude enough filament to fill the gaps between the lines and create a smooth and solid first layer. This can result in poor adhesion, curling, warping, or detachment of the print from the bed12.
To improve adherence on the first layer, the user should raise the filament flow amount slightly, such as 105% or 110%, to ensure that enough filament is extruded to create a strong bond with the bed. The user should also make sure that the nozzle height, bed leveling, and bed temperature are properly calibrated for optimal first layer adhesion12.
The other options are less likely to improve adherence on the first layer, because:
*Lowering the print bed temperature may reduce the adhesion of the TPU filament to the bed, as TPU usually requires a bed temperature between 20-60°C for the best results3. Lowering the bed temperature may also increase the risk of warping or curling of the print4.
*Adjusting the RPM of the cooling fan may not have a significant effect on the first layer adhesion, as cooling fans are not required with TPU3. In fact, using a cooling fan with TPU may cause cracking or delamination of the print, as TPU needs to cool down slowly and evenly4.
*Increasing the print speed may worsen the first layer adhesion, as TPU is a flexible and elastic filament that needs to be printed slowly and consistently. A recommended print speed for TPU is 15-30mm/s3. Increasing the print speed may cause clogging, stringing, blobs, or under-extrusion of the filament4.
For more information and tips on how to 3D print TPU filament like a pro, you can visit these links:
*How to 3D Print TPU Filament Like a Pro - Ultimate Guide & FAQ
*The Complete TPU Filament 3D Printing Guide - 3DSourced
*TPU Filament 3D Printing Material - The Complete Guide
*TPU filament - learn everything about the TPU material for 3D printing
質問 # 325
技術者が顧客のラップトップの Wi-Fi 接続の問題のトラブルシューティングを行っています。ラップトップは接続しますが、断続的に切断されます。技術者は、ワイヤレス カードが正しく取り付けられており、ルーターの設定が正しく、ワイヤレス信号の強度が正常であることをすでに確認しています。技術者が次に調査すべきものは次のうちどれですか?
- A. 無線周波数
- B. ファイアウォールの設定
- C. 接続されているデバイスの数
- D. MACアドレスフィルター
正解:A
解説:
The next thing that the technician should investigate is D. Radio frequency.
Radio frequency is the range of electromagnetic waves that are used to transmit wireless signals. Different devices and networks use different radio frequencies, such as 2.4 GHz or 5 GHz, to communicate with each other. If there are multiple devices or networks using the same or overlapping radio frequencies, they can interfere with each other and cause Wi-Fi connection issues, such as intermittent disconnections, slow speeds, or poor quality .
To fix this issue, the technician can try changing the radio frequency or channel of the router or the laptop, to avoid interference from other sources. The technician can also use a tool such as Wi-Fi Analyzer to scan the nearby wireless networks and find the best frequency or channel to use. Alternatively, the technician can move the router or the laptop to a different location, away from potential sources of interference, such as cordless phones, microwaves, Bluetooth devices, or other routers .
The other options are less likely to be the reason for the issue. Firewall settings are software configurations that control the network traffic and security of a device. They may block some websites or applications from accessing the internet, but they should not affect the Wi-Fi connection itself. MAC address filter is a feature that allows the router to restrict access to specific devices based on their MAC addresses, which are unique identifiers for network interfaces. If the MAC address filter is enabled and the laptop's MAC address is not on the allowed list, it will not be able to connect to the Wi-Fi network at all, not intermittently. Number of connected devices is the amount of devices that are using the same Wi-Fi network at the same time. This may affect the network performance or bandwidth, but it should not cause intermittent disconnections, unless the network is overloaded or unstable.
References:
1: How To Fix WiFi Connection Problems - Help Desk Geek
2: How to Fix Your WiFi Connection Problems - Lifewire
3: Wi-Fi Analyzer - Apps on Google Play
質問 # 326
管理者はサーバーの 15,000rpm ハード ドライブを交換しています。ドライブが使用する可能性が最も高いインターフェイスの種類は次のうちどれですか?
- A. eSATA
- B. SAS
- C. SATA
- D. IDE
正解:B
解説:
SAS (Serial Attached SCSI) is an interface type that supports high-speed data transfer and high-performance hard drives, such as 15,000rpm drives. SAS drives are commonly used in servers that require fast access and reliability. IDE (Integrated Drive Electronics), eSATA (external SATA), and SATA (Serial ATA) are not suitable for 15,000rpm drives, as they have lower speed and performance.
質問 # 327
ユーザーは、週に数日自宅で仕事をしているときにタブレット上の安全なアプリケーションにアクセスできませんが、オフィスにいるときはアプリケーションが動作します。リモートワークを可能にするために再構成する必要がある可能性が高いサービスは次のどれですか。
- A. 近距離無線通信
- B. 全地球測位システム
- C. モバイルデバイス管理
- D. Wi-Fi 保護アクセス
正解:C
解説:
Comprehensive and Detailed In-Depth Explanation:
Mobile Device Management (MDM) software often controls access to corporate resources based on location, network, or VPN status. If the MDM is not configured to allow access from outside the office or via home networks, the apps may be blocked. This is the most probable cause if apps work only on-premises.
* Option A: GPS is used for location services, not access control.
* Option C: WPA is a Wi-Fi security protocol, not related to access restrictions.
* Option D: NFC enables close-range communication - irrelevant to app access.
CompTIA A+ Core 1 Exam Objective Reference:
* Objective 1.6: Given a scenario, configure basic mobile device network connectivity and application support.
質問 # 328
技術者はデスクトップ PC で作業しており、その NIC が機能していることを確認したいと考えています。技術者は次のうちどれを使用する必要がありますか?
- A. ループバックプラグ
- B. ネットワークタップ
- C. ケーブルテスター
- D. トナープローブ
正解:A
質問 # 329
顧客のローラさんは、ホーム オフィスのワイヤレス アクセス ポイントを構成するように指示しました。
彼女はワイヤレス ネットワークを財務に使用する予定であり、ネットワークを可能な限り高度な暗号化で設定することを要求しました。
さらに、ローラは、隣人が無線ネットワークを使用していることを知っており、自分のネットワークが他のネットワークによって干渉されていないことを確認したいと考えています。
彼女は、デフォルト設定を次のように変更することを要求します。
ワイヤレス名: HomeWiFi
共有キー: CompTIA
ルーターのパスワード: Secure$1
最後に、ローラは自分のラップトップとスマートフォンだけがネットワークに接続できるようにしたいと考えています。
ラップトップ: IP アドレス 192.168.1.100
ハードウェアアドレス: 00:0A:BF:03:C4:54
スマートフォン:IPアドレス 192.168.1.101
ハードウェアアドレス: 09:2C:D0:22:3F:11
手順
ネットワーク アダプター ウィンドウを使用して、Laura のワイヤレス ネットワークを構成します。
初期状態に戻したい場合は、「すべてリセット」ボタンをクリックしてください。



正解:
解説:
See the explanation below
Explanation:
solution as


質問 # 330
次のクラウド モデルのうち、顧客がハードウェアと OS レイヤーについては責任を負わず、データとアプリケーションについては責任を負うのはどれですか。
- A. SaaS
- B. CaaS
- C. IaaS
- D. PaaS
正解:D
質問 # 331
技術者が RAID 5 アレイ内の故障したドライブを交換しています。アレイからドライブをホットスワップする前に技術者が最初に実行する必要がある手順は次のうちどれですか。
- A. 交換日を記録します。
- B. アレイをシャットダウンする_
- C. 故障したドライブを安全に処分します。
- D. 完全バックアップを実行する
正解:D
解説:
The answer is D. Perform a full backup.
Before replacing a failed drive in a RAID 5 array, the technician should perform a full backup of the data on the array to ensure that no data is lost during the hot swapping process. Hot swapping is the process of replacing a drive without shutting down the system or the array, which allows for faster recovery and minimal downtime. However, hot swapping also involves some risks, such as accidentally removing the wrong drive, damaging the new drive, or encountering another drive failure during the rebuild process. Therefore, performing a full backup is a precautionary measure that can prevent data loss in case of any unexpected errors or complications.
The other options are not the first steps that the technician should take before hot swapping the drive. Documenting the replacement date is a good practice, but it is not as important as backing up the dat a) Shutting down the array is not necessary for hot swapping, and it may cause more disruption to the system or the users. Safely disposing of the failed drive is a step that should be done after replacing it, not before.
Reference:
Hot-swapping the hard drives when the RAID crashes | QNAP, section "Install a new drive to rebuild RAID 5 by hot swapping": "Important: Do not install a new drive when the system is not in degraded mode, otherwise you may encounter unexpected system failures." Hot Swapping hard drives on Raid 5 with data on them - Spiceworks Community, reply by Magnus369: "Part of that slowness would be the raid level you are using. Highly doubt you can change it without losing data either, but your writes are going to be atrociously slow due to having to figure out parity across 11 drives for each write you do. While you may have a ton of space, it's unstable and subject to self destruction." hard drive - How do I Change a damaged Disk in a Raid 5 array - Server Fault, answer by Chris S: "If you have another disk failure during rebuild you will lose all your data."
質問 # 332
SOHO ネットワーク上のユーザーは、240 ピクセルであってもオンライン ビデオを視聴できません。技術者はユーザーのコンピュータから ipconfig を実行し、次の内容を記録します。
次に、技術者は、ユーザーの Cat 5 ケーブルを介してテスト ラップトップをルーターに接続し、次の情報を記録します。
ユーザーの問題の原因として最も考えられるのは次のうちどれですか?
- A. ネットワークケーブルが不良です
- B. IPアドレスが間違っています
- C. デフォルト ゲートウェイの構成が間違っています
- D. NIC の故障
正解:D
解説:
Based on the information recorded by the technician, the network connection appears to be functioning normally. The user's computer is properly configured with an IPv4 address, subnet mask, and default gateway, which should allow the user to access the internet and online videos. The high download and upload speeds and low ping time recorded from the test laptop also indicate that the network is working well. However, the user's inability to watch online videos suggests that there might be an issue with the network card (NIC) on the user's computer. The NIC might be faulty or malfunctioning, which is preventing the computer from receiving and processing the video data. The technician should try replacing the NIC to resolve the issue.
質問 # 333
技術者は、エンド ユーザーが古いハイエンド デスクトップ コンピューター用に注文した、故障したマザーボードをアップグレードしています。ただし、技術者は CPU をソケットに取り付けることができません。技術者は詳しく検査すると、CPU のピンがソケットと一致していないことに気づきました。技術者が次にとるべき最善の行動は次のうちどれですか?
- A. ソケットの種類とメーカーを確認してください。
- B. CPU と互換性のあるマザーボードを見つけます。
- C. アダプターを取り付けてユニバーサルソケットを作成します。
- D. できるだけ多くのピンを設定するようにしてください。
正解:A
解説:
Explanation
In this situation, the best course of action for the technician to take NEXT would be C. Verify the socket type and manufacturer. If the pins on the CPU do not line up with the socket on the motherboard, it is likely that there is a compatibility issue between the two components. The technician should verify that the socket type and manufacturer of the motherboard match those of the CPU to ensure that they are compatible.
質問 # 334
技術者が 2 つの DIMM で PC をアップグレードし、合計 32 GB にします。2 つの DIMM をインストールした後、ユーザーは OS が 16 GB しか報告していないことに気付きました。技術者は、問題を可能な限り迅速かつコスト効率よく解決するために、次のどのタスクを実行する必要がありますか。
- A. OS を最新バージョンに更新します。
- B. 最近のシステム更新をロールバックします。
- C. 故障したマザーボードを交換してください。
- D. 別のスロットに RAM を再インストールします。
正解:D
解説:
Reinstalling RAM in different slots addresses possible issues with dual-channel configurations.
If not installed correctly, the system might not recognize the full capacity.
This solution is immediate and doesn't incur extra costs, unlike replacing hardware.
It reflects CompTIA A+ Core 1 exam objectives on hardware troubleshooting, specifically RAM installation and configuration.
質問 # 335
ユーザーがストリーミング メディア デバイスをホテルのツリー ワイヤレス インターネットに接続しようとしていますが、ユーザーはキャプティブ ポータルを通過できません。ユーザーがデバイスをインターネットに接続できる可能性が最も高いのは次のうちどれですか?
- A. Wi-Fi 上のキャプティブ ポータルを無効にするようホテルに依頼する
- B. ユーザーのデバイスのホットスポットに接続します
- C. デバイスの日付とタイムスタンプを調整して別の国を反映する
- D. デバイスの Wi-Fi セキュリティを無効にする
正解:B
解説:
A captive portal is a web page that requires users to agree to terms and conditions, enter credentials, or provide payment information before accessing a wireless network. Some devices, such as streaming media devices, may not have a web browser or a user interface to interact with the captive portal. One possible solution is to connect to the hotspot on the user's device, such as a smartphone or a tablet, and use it as a bridge to access the internet through the wireless network. The user's device can authenticate with the captive portal and share its internet connection with other devices via Wi-Fi, Bluetooth, or USB. Reference: https://partners.comptia.org/docs/default-source/resources/a-core-1-content-guide (page 12)
質問 # 336
......
A+無料認定試験材料はPassTestが提供された865問題:https://www.passtest.jp/CompTIA/220-1101J-shiken.html