5V0-21.21試験をパスするなら弊社のVMware Certified Master Specialist試験パッケージを今すぐゲットして合格せよ [Q14-Q32]

Share

5V0-21.21試験をパスするなら弊社のVMware Certified Master Specialist試験パッケージを今すぐゲットして合格せよ

完全版最新の2024年最新の5V0-21.21試験問題集テストガイド、専門トレーニングPassTest

質問 # 14
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

  • A. 50% of the reads comes from vSAN hosts on the remote site
  • B. 50% of the reads comes from vSAN hosts on the local site
  • C. 100% of the reads comes from vSAN hosts on the local site
  • D. 100% of the reads comes from vSAN hosts on the remote site

正解:C

解説:
vSAN stretched clusters uses a read locality algorithm to read 100% from the data copy on the local site. Read locality reduces the latency incurred during reading operations.
https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/techpaper/VMware-Virtual- SAN-6.2-Stretched-Cluster-Guide.pdf/subassets/page92.pdf


質問 # 15
Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

  • A. Bandwidth is unnecessarily sent across the inter-site link.
  • B. When a site is disconnected, the VM will continue to have access to its VMDK.
  • C. Proper policies result in higher inter-site bandwidth utilization.
  • D. When a site is disconnected, the VM will lose access to its VMDK.

正解:B


質問 # 16
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system.
The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?

  • A. A 16GB single-level cell (SLC) SATADOM device must be used.
  • B. A 4GB USB or SD device must be used.
  • C. ESXi Hosts must boot from a PMEM device.
  • D. A 16GB multiple-level cell (MLC) SATADOM device must be used.

正解:A

解説:
If the memory of the ESXi host has 512 GB of memory or less, you can boot the host from a USB, SD, or SATADOM device.
If the memory of the ESXi host has more than 512 GB, consider the following guidelines.
You can boot the host from a SATADOM or disk device with a size of at least 16 GB. When you use a SATADOM device, use a single-level cell (SLC) device.
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-
planning.doc/GUID-B09CE19D-A3F6-408C-AE69-35F65CBE66E1.html


質問 # 17
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.
Which three prerequisites must be satisfied before completing the task? (Choose three.)

  • A. Create an encryption storage policy
  • B. Enable Data-In-Transit encryption first
  • C. Enable that the virtual machines are powered on
  • D. Verify if a role with privilege "Cryptographic operations.Encrypt new" is assigned
  • E. Establish a trusted connection with the KMS
  • F. Verify if a role with privilege "Cryptographic operations.Migrate" is assigned

正解:C、D、E


質問 # 18
An administrator is setting up vSAN file services on a vSAN cluster but is unable to join the vSAN File Services to the domain.
Which two possible reasons could explain this failure? (Choose two.)

  • A. The administrator wanted to register the file services to a sub-domain.
  • B. The administrator was using pre-created computer objects for the file services in the Active Directory.
  • C. The administrator did not pre-create a dedicated organizational unit in Active Directory.
  • D. A read-only domain controller was being used.
  • E. The administrator was using IP addresses from an IP pool.

正解:A、D

解説:
https://docs.vmware.com/en/VMware-vSphere/8.0/vsan-administration/GUID-CA9CF043-9434-454E-86E7-DCA9AD9B0C09.html


質問 # 19
A vSAN administrator notices that all the applications on a vSAN cluster are suffering from performance degradation. The main applications on this cluster are very random write-intensive and generate a lot of i/o. De-staging seems to be going awfully slow.
Given the following information:
- Each host has a single disk group.
- Each disk group has 7 capacity disks.
- The size of each cache disk is 600 GB.
How should the administrator solve this problem?

  • A. Increase the size of cache disks
  • B. Add more capacity disks
  • C. Add more cache disks
  • D. Add additional disk groups

正解:A


質問 # 20
A vSAN architect is reviewing an RFP (Request For Proposal) that has the following vSAN Ready Nodes requirements:
- CPU upgrades every two years.
- SAS drives will be changed to NVMe drives after one year.
- Introduce additional IO controllers to enhance performance.
What should the architect consider when writing the response?

  • A. CPU upgrades are supported with only specific vSAN Ready Nodes.
    Changing the drive protocol in a vSAN Ready Node is only supported with HCI appliances.
    Only OEM-provided IO controllers can be added.
  • B. CPU upgrades requires opening a case with GSS.
    Changing the drive protocol in a vSAN Ready Node requires disk wipeout.
    Any OEM IO controller can be added.
  • C. CPU upgrades are supported.
    Changing the drive protocol in a vSAN Ready Node is not supported.
    Only tested and certified IO controllers can be added.
  • D. CPU upgrades are not supported.
    Changing the drive protocol in a vSAN Ready Node is supported.
    Any HCL certified IO controllers can be added.

正解:C


質問 # 21
During a vSAN design workshop, an architect collected these customer requirements:
* Leverage vSAN storage policies with Erasure Coding.
* Enable Deduplication and Compression.
* Use the minimum number of hosts in the cluster.
* Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?

  • A. Six nodes All-Flash vSAN cluster
  • B. Five nodes All-Flash vSAN cluster
  • C. Five nodes Hybrid vSAN cluster
  • D. Six nodes Hybrid vSAN cluster

正解:A

解説:
Reference: https://www.vmware.com/files/pdf/products/vsan/vmware-vsan-62-space-efficiency- technologies.pdf


質問 # 22
Which two statements regarding networking are true for a vSAN Stretched Cluster? (Choose two.)

  • A. A Stretched Layer 2 network is required at the vSAN data sites and at the witness site.
  • B. The vSAN data network must communicate with the vSAN witness host.
  • C. PIM is required for stretched vSAN clusters.
  • D. a 5ms RTT or less is required between the data sites.
  • E. A Stretched Cluster can use Layer 2 or Layer 3 communication for the vSAN network.

正解:D、E


質問 # 23
An administrator is troubleshooting vSAN performance issues, and the performance diagnostics reports:
"There are errors seen in one or more physical NICs on one or more hosts." Which two problems must be resolved to fix this issue? (Choose two.)

  • A. There is an incorrectly set MTU.
  • B. A firewall is blocking ports.
  • C. There are incompatible firmware and driver versions.
  • D. The vSAN version needs to be upgraded to 7.0.
  • E. A 25 Gb/s NIC needs to be installed.

正解:A、C


質問 # 24
A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

  • A. Remove from vSAN cluster
  • B. Place the host in maintenance mode with Full Data migration
  • C. Place the host in maintenance mode with Ensure Accessibility
  • D. Delete the disk group(s) on the legacy host
  • E. Disconnect from vCenter Server
  • F. Place the host in maintenance mode with no data migration

正解:A、B、D


質問 # 25
An architect intends to use the Primary Level of Failures To Tolerate (PFTT) to calculate the minimum number of required hosts for a vSAN cluster.
Which calculation model should be used?

  • A. 1 * PFTT + 2
  • B. 1 * PFTT + 1
  • C. 2 * PFTT + 2
  • D. 2 * PFTT + 1

正解:D


質問 # 26
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses two different vSAN storage policies for running the workloads depending on the applications requirements:
- Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
- Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
- Preferred Site - Preferred Site workloads should run on DC1 hosts.
- Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two actions should the administrator take to ensure that there is no impact to production services before completing the maintenance window in the Preferred Site? (Choose two.)

  • A. Update the Preferred Site vSphere DRS affinity rule to be "Must run on hosts in group".
  • B. Update the Preferred Site vSphere DRS affinity rule to be "Should not run on hosts in group".
  • C. Update the Secondary Site vSphere DRS affinity rule to be "Must run on hosts in group".
  • D. Change the Host Groups in the Secondary Site rule to the DC1 hosts.
  • E. Change the Host Groups in the Preferred Site rule to the DC2 hosts.

正解:B、C


質問 # 27
An administrator is reviewing the root cause analysis of a failure event that resulted in vSAN Data Loss. The following information is known about the event:
1. The RAID battery-replacing procedure on one of the first vSAN cluster node took much more time than the vSAN administrator predicted.
2. The only Storage policy has a Primary level of Failures To Tolerate = 1.
3. Whilst the first host was in maintenance mode, another node failure occurred, causing da-ta loss in the vSAN cluster.
The administrator needs to update the procedure for completing maintenance on the cluster.
Which Maintenance Mode option should the administrator choose to ensure that data loss does not occur in the future?

  • A. Full data migration
  • B. No data migration with selected option 'Move powered-off and suspended virtual machines to other hosts in the cluster'
  • C. No data migration
  • D. Ensure accessibility

正解:A


質問 # 28
Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

  • A. Bandwidth is unnecessarily sent across the inter-site link.
  • B. When a site is disconnected, the VM will continue to have access to its VMDK.
  • C. Proper policies result in higher inter-site bandwidth utilization.
  • D. When a site is disconnected, the VM will lose access to its VMDK.

正解:B

解説:
Setting proper VM/Host Group Rules and VM Storage Policy Affinity Rules are beneficial for several reasons Bandwidth is not unnecessarily sent across the inter-site link Lower inter-site bandwidth utilization In the situation where the alternate site is disconnected, the VM will continue to have access to its vmdk. from https://core.vmware.com/resource/vsan-stretched-cluster-guide#sec7341-sub5


質問 # 29
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?

  • A. All objects on the affected host will be lost.
  • B. All objects will remain accessible.
  • C. A rebuild of the affected objects will occur.
  • D. The cluster will be partitioned and the vSAN host will need to be rejoined.

正解:B

解説:
Default Storage Policy is FTT=1. https://docs.vmware.com/en/VMware-vSphere/6.7/com.vmware.vsphere.virtualsan.doc/GUID-C228168F-6807-4C2A-9D74-E584CAF49A2A.html


質問 # 30
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)

  • A. The cluster DRS threshold has been set to Aggressive.
  • B. The object repair timer value has been increased.
  • C. There is a vSAN node failure.
  • D. The vSAN policy protection level has changed from FTT=0 to FTT=1.
  • E. The vSAN Resync throttling is enabled.

正解:C、D


質問 # 31
An organization has two vSAN clusters managed by the same vCenter server, each providing
100 TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 40% of its storage capacity.
The company also has the following:
- an iSCSI array of 300 TB, which runs at 76% of its capacity
- a NAS system of 200 TB, which runs at 10% of its capacity
- a Fiber channel (FC) array of 300 TB, which runs at 80% of its capacity The administrator is asked to add an additional 25 TB of storage to the first cluster but is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Use the FC array to obtain additional free capacity.
  • B. Use the NAS to obtain additional free capacity.
  • C. Use the iSCSI array to obtain additional free capacity.
  • D. Use an HCI Mesh to obtain additional capacity.

正解:D


質問 # 32
......

2024年最新の問題VMware Certified Master Specialist合格目指して5V0-21.21リアル試験をマスターせよ!:https://www.passtest.jp/VMware/5V0-21.21-shiken.html

練習問題5V0-21.21には画期的なVMware HCI Master Specialist練習試験問題:https://drive.google.com/open?id=1b73zXWloS9WofYakl_gc8ggIK1C20j0j