質問 # 20
Which two VSP systems support attached Drive Box Flash (DBF)? (Choose two.)

  • A. VSP F700
  • B. VSP F370
  • C. VSP E590
  • D. VSP G900

正解:A、C


質問 # 21
You need to replace a failing power supply (PS) in a VSP E590.
What is the correct procedure?

  • A. Use the Maintenance Utility for blocking the controller, then replace the PS.
  • B. Use the Maintenance Utility for blocking the PS, then replace it.
  • C. Check if the status of the PS is blocked, and if yes, then replace it directly.
  • D. Use the MPC for blocking the PS, then replace it.

正解:D


質問 # 22
Which two tools are available to configure NTP server settings on a VSP E590 system? (Choose two.)

  • A. Storage Navigator
  • B. Initial Setup Wizard
  • C. HSA Embedded
  • D. Maintenance Utility

正解:B、D


質問 # 23
Which three RAID configurations are supported by VSP Midrange systems? (Choose three.)

  • A. 7D + 1P
  • B. 4D + 1P
  • C. 10D + 2P
  • D. 8D + 1P
  • E. 2D + 2D

正解:B、C、D


質問 # 24
The SVP of a VSP G900 system failed and you have been asked to replace it.
Which two items must be available to perform the replacement? (Choose two.)

  • A. the microcode iso file with the correct software versions
  • B. the iso file with the correct version of the Windows operating system
  • C. the iso file with the correct version of Hitachi Ops Center
  • D. the Hitachi Remote Ops Monitor Agent iso file

正解:A、C


質問 # 25
A customer has a VSP G370 with the encryption license key installed. They now want to have all the DP-Volumes of a certain pool located on encrypted RAID Groups.
What are two requirements? (Choose two.)

  • A. The RAID level of RAID Groups in the pool must be RAID 6.
  • B. At least 20 GB of Shared Memory must be installed.
  • C. The controller board must support encryption.
  • D. The RAID Groups in the pool must be formatted with encryption enabled.

正解:C、D


質問 # 26
Your customer wants to connect multiple servers to a new port on a VSP G700. The correct topology has already been set for the port.
What should you do next?

  • A. Create a Host Group.
  • B. Enable Host Group security.
  • C. Scan for all WWNs.
  • D. Enable Port Security.

正解:C


質問 # 27
Which two reconfiguration activities are performed without interrupting host access on a VSP Gx00 system? (Choose two.) Choose 2 answers

  • A. upgrading from G200 to G800
  • B. adding a DKB
  • C. adding a DB60 drive tray
  • D. upgrading from G200 to G600

正解:B、C


質問 # 28
Which tool do you use to install license keys on a VSP G370 system?

  • A. Storage Navigator
  • B. HSA Embedded
  • C. MPC Software
  • D. Maintenance Utility

正解:D


質問 # 29
You need to replace a broken disk drive on a VSP G700.
What are two prerequisites? (Choose two.)

  • A. The Drive Box where the drive is located must be powered down.
  • B. The red LED on the drive must be lit.
  • C. You must use the Replace button in the Maintenance Utility before removing the drive.
  • D. You must wear a wrist strap for ESD protection.

正解:C、D


質問 # 30
Which tool can be used to change System Option Modes (SOMs)?

  • A. Hitachi Ops Center
  • B. Webconsole
  • C. HSAe
  • D. MPC software

正解:D


質問 # 31
A customer wants to change a production RAID group from RAID 5 (7D+1P) to RAID 6 (6D+2P) on a VSP G600 during normal operations. They have just unmapped the LUNs from the channel ports.
What needs to be performed next?

  • A. The RAID 5 group must be put into DRU mode in Storage Navigator.
  • B. The RAID level in the SVP Maintenance window must be changed.
  • C. Parity groups must be deleted.
  • D. The RAID level must be changed in Storage Navigator.

正解:C


質問 # 32
What are two consequences when a "New Installation" procedure is performed on a VSP Midrange system? (Choose two.)

  • A. The license keys are deleted.
  • B. The SVP drive is formatted.
  • C. The MPC software is updated.
  • D. All the data on RAID groups is lost.

正解:B、D


質問 # 33
A customer wants to change a production RAID Group from RAID 5 (7D+1P) to RAID 6 (6D + 2P) on a VSP G700 during normal operations. They have just unmapped the LUNs from the channel ports.
What needs to be performed next?

  • A. The RAID Group must be deleted.
  • B. The RAID 5 Group must be put into DRU mode in Storage Navigator.
  • C. The RAID level must be changed in the SVP Maintenance window.
  • D. The RAID level must be changed in Storage Navigator.

正解:C


質問 # 34
......

有効なHQT-4180試験 最新問題で2023年最新の学習ガイド:https://www.passtest.jp/Hitachi/HQT-4180-shiken.html

トップクラスHitachi HQT-4180試験最先端学習ガイド!練習問題バージョン:https://drive.google.com/open?id=1O2Pug33BXnwdXtySTOmxr1MpmAGDrIB6