HQT-4180認定お試し[2023年05月25日] 最新HQT-4180のPDF問題集
ベストHitachi HQT-4180学習ガイドと問題集でof2023年更新
質問 # 20
Which two VSP systems support attached Drive Box Flash (DBF)? (Choose two.)
- A. VSP F700
- B. VSP F370
- C. VSP E590
- D. VSP G900
正解:A、C
質問 # 21
You need to replace a failing power supply (PS) in a VSP E590.
What is the correct procedure?
- A. Use the Maintenance Utility for blocking the controller, then replace the PS.
- B. Use the Maintenance Utility for blocking the PS, then replace it.
- C. Check if the status of the PS is blocked, and if yes, then replace it directly.
- D. Use the MPC for blocking the PS, then replace it.
正解:D
質問 # 22
Which two tools are available to configure NTP server settings on a VSP E590 system? (Choose two.)
- A. Storage Navigator
- B. Initial Setup Wizard
- C. HSA Embedded
- D. Maintenance Utility
正解:B、D
質問 # 23
Which three RAID configurations are supported by VSP Midrange systems? (Choose three.)
- A. 7D + 1P
- B. 4D + 1P
- C. 10D + 2P
- D. 8D + 1P
- E. 2D + 2D
正解:B、C、D
質問 # 24
The SVP of a VSP G900 system failed and you have been asked to replace it.
Which two items must be available to perform the replacement? (Choose two.)
- A. the microcode iso file with the correct software versions
- B. the iso file with the correct version of the Windows operating system
- C. the iso file with the correct version of Hitachi Ops Center
- D. the Hitachi Remote Ops Monitor Agent iso file
正解:A、C
質問 # 25
A customer has a VSP G370 with the encryption license key installed. They now want to have all the DP-Volumes of a certain pool located on encrypted RAID Groups.
What are two requirements? (Choose two.)
- A. The RAID level of RAID Groups in the pool must be RAID 6.
- B. At least 20 GB of Shared Memory must be installed.
- C. The controller board must support encryption.
- D. The RAID Groups in the pool must be formatted with encryption enabled.
正解:C、D
質問 # 26
Your customer wants to connect multiple servers to a new port on a VSP G700. The correct topology has already been set for the port.
What should you do next?
- A. Create a Host Group.
- B. Enable Host Group security.
- C. Scan for all WWNs.
- D. Enable Port Security.
正解:C
質問 # 27
Which two reconfiguration activities are performed without interrupting host access on a VSP Gx00 system? (Choose two.) Choose 2 answers
- A. upgrading from G200 to G800
- B. adding a DKB
- C. adding a DB60 drive tray
- D. upgrading from G200 to G600
正解:B、C
質問 # 28
Which tool do you use to install license keys on a VSP G370 system?
- A. Storage Navigator
- B. HSA Embedded
- C. MPC Software
- D. Maintenance Utility
正解:D
質問 # 29
You need to replace a broken disk drive on a VSP G700.
What are two prerequisites? (Choose two.)
- A. The Drive Box where the drive is located must be powered down.
- B. The red LED on the drive must be lit.
- C. You must use the Replace button in the Maintenance Utility before removing the drive.
- D. You must wear a wrist strap for ESD protection.
正解:C、D
質問 # 30
Which tool can be used to change System Option Modes (SOMs)?
- A. Hitachi Ops Center
- B. Webconsole
- C. HSAe
- D. MPC software
正解:D
質問 # 31
A customer wants to change a production RAID group from RAID 5 (7D+1P) to RAID 6 (6D+2P) on a VSP G600 during normal operations. They have just unmapped the LUNs from the channel ports.
What needs to be performed next?
- A. The RAID 5 group must be put into DRU mode in Storage Navigator.
- B. The RAID level in the SVP Maintenance window must be changed.
- C. Parity groups must be deleted.
- D. The RAID level must be changed in Storage Navigator.
正解:C
質問 # 32
What are two consequences when a "New Installation" procedure is performed on a VSP Midrange system? (Choose two.)
- A. The license keys are deleted.
- B. The SVP drive is formatted.
- C. The MPC software is updated.
- D. All the data on RAID groups is lost.
正解:B、D
質問 # 33
A customer wants to change a production RAID Group from RAID 5 (7D+1P) to RAID 6 (6D + 2P) on a VSP G700 during normal operations. They have just unmapped the LUNs from the channel ports.
What needs to be performed next?
- A. The RAID Group must be deleted.
- B. The RAID 5 Group must be put into DRU mode in Storage Navigator.
- C. The RAID level must be changed in the SVP Maintenance window.
- D. The RAID level must be changed in Storage Navigator.
正解:C
質問 # 34
......
有効なHQT-4180試験 最新問題で2023年最新の学習ガイド:https://www.passtest.jp/Hitachi/HQT-4180-shiken.html
トップクラスHitachi HQT-4180試験最先端学習ガイド!練習問題バージョン:https://drive.google.com/open?id=1O2Pug33BXnwdXtySTOmxr1MpmAGDrIB6