質問 154
Regarding the adjustable battery of UPS5000-E, when one battery is broken, at least () battery needs to be removed? Then set the corresponding number of battery cells on the monitoring panel.
- A. 0
- B. 1
- C. 2
- D. 3
正解: D
質問 155
In NETECO's report management, which of the following types does periodic tasks have? (Multiple choice)
- A. The Times
- B. Weekly report
- C. The Daily
- D. Monthly report
正解: A,B,C,D
質問 156
NETCOL5000-C temperature and humidity sensor dial-code setting error may cause:
- A. The temperature and humidity sensor cannot detect the temperature and humidity
- B. Water leakage at the bottom of the device
- C. The return air temperature or fan speed fluctuates greatly
- D. The drainage capacity of the equipment is significantly reduced
正解: A
質問 157
What is the channel type of a typical configuration of FusionModule800? Is a cold aisle or a hot aisle?
- A. Cold Aisle
- B. Hot Aisle
正解: A
質問 158
Which of the following models has the widest input voltage range and is more suitable for harsh power grids?
- A. Eaton 9395
- B. UPS5000-A
- C. APC Galaxy7000
- D. Emerson NXF
正解: B
質問 159
What sensor does FusionModule2000 use to detect whether the air conditioner is leaking?
- A. Multifunctional sensor
- B. Water Immersion Sensor
- C. Infrared sensor
- D. Temperature sensor
正解: B
質問 160
Which of the following are the accessories for UPS5000-A-400/500K? (Multiple choice)
- A. Upper air outlet assembly
- B. Dry contact expansion board
- C. Port battery inspection instrument
- D. Battery temperature sensor
正解: A,C,D
質問 161
By setting the mailbox parameters, the NETECO system will send emails to notify users according to the set rules.
- A. False
- B. True
正解: B
質問 162
Which of the following alarm functions does the main circuit of the PDU800 power distribution cabinet have? (Multiple choice)
- A. Undervoltage alarm
- B. Current high reading value out-of-limit alarm
- C. Overvoltage alarm
- D. Abnormal frequency
- E. The main circuit is powered off
正解: A,B,C,D,E
質問 163
The access control management function of the Netco6000 management system only supports one-way card swiping (you need to swipe your card to enter the door, and press the exit button to go out), but do not support two-way card swipe (you need to swipe your card to enter the door and go out).
- A. False
- B. True
正解: A
質問 164
A NetCol5000-A compressor cannot run, what are the possible reasons? (Multiple choice)
- A. Compressor circuit breaker open
- B. High voltage switch action
- C. Indoor fan failure
- D. Damaged compressor motor
正解: A,B,C,D
質問 165
For a 12V battery, which of the following voltages are acceptable for normal use? (Multiple choice)
- A. 10.02V
- B. 14.1V
- C. 13V
- D. 14.52V
正解: B,C,D
質問 166
Which of the following UPS models supports bypass hot swap? (Multiple choice)
- A. UPS5000-E
- B. PX250 series
- C. APM series
- D. UPS5000-A
正解: A,B,C
質問 167
The PDU8000 precision power distribution cabinet supports the monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.
- A. False
- B. True
正解: A
質問 168
During the use of the battery, in order to reduce the deterioration of the trend of voltage imbalance between batteries, it is necessary to increase the charging voltage of the battery pack, activate and charge the battery, and prolong the battery life. The maintenance method is called ().
- A. Float charge
- B. Charging test
- C. Equalizing Charge
- D. Self-discharge
正解: C