H12-425_V2.0問題集には練習試験問題解答
H12-425_V2.0はHCIP-DCF-BFDO実際の無料試験練習テスト
質問 # 193
When configuring temperature control products, if the temperature of the project location is -10 -30 °C, which of the following working conditions should be preferred?
- A. Wide temperature (-40-55 ℃ )
- B. T1 (-20°-45°C)
- C. T3 (-20-55 ℃ )
- D. Ultra-low temperature (-40-45 ℃ )
正解:B
質問 # 194
What is the maximum power of the IT cabinet of FusionModule500 & FusionModule800?
- A. 9KVA
- B. 3KVA
- C. 7KVA
- D. 5KVA
正解:C
質問 # 195
When the polling function is turned on, the running machine and the standby machine can be exchanged, thereby improving the average lifespan.
- A. FALSE
- B. TRUE
正解:B
質問 # 196
What methods are supported by the FusionModule800 UPS configuration?
- A. N/N+1/2N
- B. N/N+1
- C. N/2N
正解:A
質問 # 197
UPS5000-E (50kVA power module) single rack can accommodate up to 300kVA.
- A. False
- B. True
正解:B
質問 # 198
In this agenda, the refrigerant has undergone the change process of high-pressure gas, high-pressure liquid, low-pressure liquid, and low-pressure gas. In the air-conditioning system, please sort the flow direction of the refrigerant. (Sorting question)
- A. Condenser
- B. Compressor
- C. Expansion valve
- D. Evaporator
正解:A、B、C、D
質問 # 199
The similar models of Eaton and UPS5000-A 30kVA120kVA are ().
- A. 0
- B. 1
- C. NXR
正解:A
質問 # 200
A system is configured with 5H battery backup time, and the discharge termination voltage of the battery cell should select?
- A. 1.75V
- B. 1.67V
- C. 1.80V
- D. 1.60V
正解:A
質問 # 201
AHU is the smallest module of 220kW under standard conditions and cannot be split.
- A. False
- B. True
正解:B
質問 # 202
If the FusionModule800 adopts the down pipe, what is the minimum raised floor height?
- A. 250mm
- B. 100mmn
- C. 500mm
正解:A
質問 # 203
Which of the following descriptions for the configuration of the PDU8000 modular precision power distribution cabinet is correct?
- A. The input modules of the modular precision power distribution cabinet are MCCB and ATS.
- B. Modular precision power distribution cabinet supports single and dual input
- C. The output module of the modular precision power distribution cabinet only supports 1P air switch
- D. Modular precision power distribution cabinet supports up to 4 output modules
正解:B
質問 # 204
If multiple SmartLi battery cabinets are combined, press and hold the POWER ON/OFF button on each battery management module for more than 2s, and then switch on the battery circuit breaker in any cabinet to start all battery cabinets.
- A. False
- B. True
正解:B
質問 # 205
The NETCol5000-A36W air conditioner has a light load initial function.
- A. False
- B. True
正解:A
質問 # 206
The location of the data center needs to be evaluated () factors. (Multiple choice)
- A. Cost Factors
- B. Ancillary facilities
- C. Building structure
- D. Physical and Geographical Conditions
正解:A、B、C、D
質問 # 207
Regarding the adjustable battery of UPS5000-E, when one battery is broken, at least () battery needs to be removed? Then set the corresponding number of battery cells on the monitoring panel.
- A. 0
- B. 1
- C. 2
- D. 3
正解:A
質問 # 208
A NetCol5000-A compressor cannot run, what are the possible reasons? (Multiple choice)
- A. Indoor fan failure
- B. Damaged compressor motor
- C. Compressor circuit breaker open
- D. High voltage switch action
正解:A、B、C、D
質問 # 209
The height of the FusionModule500&FusionModule800 cabinet is 24U, and both 42U are optional.
- A. False
- B. True
正解:A
質問 # 210
Among the components of UPS5000-E, which are hot-swappable? (Multiple choice)
- A. Bypass Module
- B. Power Module
- C. Dry Contact Card
- D. Energy Control Sheet
正解:A、B、C、D
質問 # 211
Which of the following humidification forms has the lowest energy consumption?
- A. Infrared humidification
- B. Wet film humidification
- C. Electrode humidification
正解:B
質問 # 212
The signal processing of the UPS5000-E will centralize control:
- A. Power Module
- B. Energy Control Module ECM
- C. Maintenance Bypass Module
- D. Bypass Module
正解:B
質問 # 213
When the inspection, maintenance and repair of electrical installations are carried out in a non-stop work mode, warning signs or signs should be hung in the electrical installations and work area.
- A. FALSE
- B. TRUE
正解:B
質問 # 214
......